About this role
<p>Requisition ID # 172076 </p> <p><p>Job Category: Engineering / Science </p> <p>Job Level: Individual Contributor</p> <p>Business Unit: Strategy & Growth</p> <p>Work Type: Hybrid</p> <p>Job Location: West Sacramento</p> <p> <p> <p> <p><p style="margin:0.0in;line-height:normal;font-size:11.0pt;font-family:Calibri, sans-serif"><strong><span style="font-size:12.0pt;font-family:Arial, sans-serif;color:black">Department Overview</span></strong></p> <p style="margin:0.0in;line-height:normal;font-size:11.0pt;font-family:Calibri, sans-serif"> </p> <p style="margin:0.0in;line-height:normal;font-size:11.0pt;font-family:Calibri, sans-serif"><span style="font-size:12.0pt;font-family:Arial, sans-serif;color:black">The hardworking coworkers of Electric Engineering ensure all manners of electric engineering—including electric standards and process safety, electric design engineering, instrumentation testing and controls, undergrounding, electric regulatory compliance and electric investment planning—are in place to safely enable a strategic and stable workplan for our Electric Operations partners. Our organization is accountable for program planning, financial budgeting, and project execution and delivery of all electric engineering projects. Electric Engineering is comprised of approximately 2,000 coworkers.</span></p> <p style="margin:0.0in;line-height:normal;font-size:11.0pt;font-family:Calibri, sans-serif"> </p> <p style="margin:0.0in;line-height:normal;font-size:11.0pt;font-family:Calibri, sans-serif"><span style="font-size:12.0pt;font-family:Arial, sans-serif;color:black">System Protection Engineering provides:</span></p> <ul style="margin-bottom:0.0in;margin-top:0.0px"> <li style="margin:0.0in 0.0in 0.0in 0.0px;line-height:normal;font-size:11.0pt;font-family:Calibri, sans-serif"><span style="font-size:12.0pt;font-family:Arial, sans-serif;color:black">Project and Maintenance &Operations support, specify design, requirements, and testing procedures.</span></li> <li style="margin:0.0in 0.0in 0.0in 0.0px;line-height:normal;font-size:11.0pt;font-family:Calibri, sans-serif"><span style="font-size:12.0pt;font-family:Arial, sans-serif;color:black">Review and analysis of power system disturbance and operations.</span></li> <li style="margin:0.0in 0.0in 0.0in 0.0px;line-height:normal;font-size:11.0pt;font-family:Calibri, sans-serif"><span style="font-size:12.0pt;font-family:Arial, sans-serif;color:black">Technical consultation and training for System Operation and Planning issues.</span></li> <li style="margin:0.0in 0.0in 0.0in 0.0px;line-height:normal;font-size:11.0pt;font-family:Calibri, sans-serif"><span style="font-size:12.0pt;font-family:Arial, sans-serif;color:black">Equipment evaluation, approval, and standard development.</span></li> </ul> <p style="margin:0.0in;line-height:normal;font-size:11.0pt;font-family:Calibri, sans-serif"> </p> <p style="margin:0.0in;line-height:normal;font-size:11.0pt;font-family:Calibri, sans-serif"><strong><span style="font-size:12.0pt;font-family:Arial, sans-serif;color:black">Position Summary</span></strong></p> <p style="margin:0.0in;line-height:normal;font-size:11.0pt;font-family:Calibri, sans-serif"> </p> <p style="margin:0.0in;line-height:normal;font-size:11.0pt;font-family:Calibri, sans-serif"><span style="font-size:12.0pt;font-family:Arial, sans-serif;color:black">This position is represented by Engineers and Scientists of California (ESC) subject to collective bargaining.</span></p> <p style="margin:0.0in;line-height:normal;font-size:11.0pt;font-family:Calibri, sans-serif"> </p> <p style="margin:0.0in;line-height:normal;font-size:11.0pt;font-family:Calibri, sans-serif"><span style="font-size:12.0pt;font-family:Arial, sans-serif;color:black">In this role as an entry level Associate Protection Engineer, you will provide support to projects, protection studies and perform protection job duties for transmission voltages 230 kV and below under direction of a supervisor or a more experienced engineer.</span></p> <p style="margin:0.0in;line-height:normal;font-size:11.0pt;font-family:Calibri, sans-serif"> </p> <p style="margin:0.0in;line-height:normal;font-size:11.0pt;font-family:Calibri, sans-serif"><span style="font-size:12.0pt;font-family:Arial, sans-serif;color:black">This position is hybrid, working from your remote office and your assigned work location based on business need. The a</span><span style="font-size:12.0pt;font-family:Arial, sans-serif">ssigned work location will be within the PG&E Service Territory.</span></p> <p style="margin:0.0in;line-height:normal;font-size:11.0pt;font-family:Calibri, sans-serif"> </p> <p style="margin:0.0in;font-size:12.0pt;font-family:'Times New Roman', serif"><span style="font-family:Arial, sans-serif">PG&E is providing the salary range that the company in good faith believes it might pay for this position at the time of the job posting. This compensation range is specific to the locality of the job. The actual salary paid to an individual will be based on multiple factors, including, but not limited to, specific skills, education, licenses or certifications, experience, market value, geographic location, collective bargaining agreements, and internal equity.</span></p> <p style="margin:0.0in;font-size:12.0pt;font-family:'Times New Roman', serif"> </p> <p style="margin:0.0in;font-size:12.0pt;font-family:'Times New Roman', serif"><span style="font-family:Arial, sans-serif">Annual salary range:</span></p> <p style="margin:0.0in;font-size:12.0pt;font-family:'Times New Roman', serif"> </p> <p style="margin:0.0in;font-size:12.0pt;font-family:'Times New Roman', serif"><span style="font-family:Arial, sans-serif">Minimum, $95,172</span></p> <p style="margin:0.0in;line-height:normal;font-size:11.0pt;font-family:Calibri, sans-serif"><span style="font-size:12.0pt;font-family:Arial, sans-serif">Maximum, $150,096</span></p> <p style="margin:0.0in;line-height:normal;font-size:11.0pt;font-family:Calibri, sans-serif"> </p> <p style="margin:0.0in;line-height:normal;font-size:11.0pt;font-family:Calibri, sans-serif"> </p> <p style="margin:0.0in;line-height:normal;font-size:11.0pt;font-family:Calibri, sans-serif"><strong><span style="font-size:12.0pt;font-family:Arial, sans-serif;color:black">Job Responsibilities</span></strong></p> <p style="margin:0.0in;line-height:normal;font-size:11.0pt;font-family:Calibri, sans-serif"> </p> <ul style="margin-bottom:0.0in;margin-top:0.0px"> <li style="margin:0.0in 0.0in 0.0in 0.0px;line-height:normal;font-size:11.0pt;font-family:Calibri, sans-serif"><span style="font-size:12.0pt;font-family:Arial, sans-serif;color:black">Provide protection engineering support for projects and studies. The engineer may perform the following job duties for transmission voltages 230 kV and below:</span></li> <li style="margin:0.0in 0.0in 0.0in 0.0px;line-height:normal;font-size:11.0pt;font-family:Calibri, sans-serif"><span style="font-size:12.0pt;font-family:Arial, sans-serif;color:black">Issue protection requirements and prepare description of operations for non-standard and localized RAS schemes</span></li> <li style="margin:0.0in 0.0in 0.0in 0.0px;line-height:normal;font-size:11.0pt;font-family:Calibri, sans-serif"><span style="font-size:12.0pt;font-family:Arial, sans-serif;color:black">Conduct short circuit studies, calculate short circuit line impedance</span></li> <li style="margin:0.0in 0.0in 0.0in 0.0px;line-height:normal;font-size:11.0pt;font-family:Calibri, sans-serif"><span style="font-size:12.0pt;font-family:Arial, sans-serif;color:black">Determine and issue relay and automatics settings</span></li> <li style="margin:0.0in 0.0in 0.0in 0.0px;line-height:normal;font-size:11.0pt;font-family:Calibri, sans-serif"><span style="font-size:12.0pt;font-family:Arial, sans-serif;color:black">Support relay system installations, such as review test program, end-to-end test, load check, direction check, relay release, etc.</span></li> <li style="margin:0.0in 0.0in 0.0in 0.0px;line-height:normal;font-size:11.0pt;font-family:Calibri, sans-serif"><span style="font-size:12.0pt;font-family:Arial, sans-serif;color:black">Conduct area coordination studies</span></li> <li style="margin:0.0in 0.0in 0.0in 0.0px;line-height:normal;font-size:11.0pt;font-family:Calibri, sans-serif"><span style="font-size:12.0pt;font-family:Arial, sans-serif;color:black">Participate in project walkdown and project meetings</span></li> <li style="margin:0.0in 0.0in 0.0in 0.0px;line-height:normal;font-size:11.0pt;font-family:Calibri, sans-serif"><span style="font-size:12.0pt;font-family:Arial, sans-serif;color:black">Provide construction drawing reviews</span></li> <li style="margin:0.0in 0.0in 0.0in 0.0px;line-height:normal;font-size:11.0pt;font-family:Calibri, sans-serif"><span style="font-size:12.0pt;font-family:Arial, sans-serif;color:black">Update and maintain records, such as Aspen relay data base, transformer data sheet, short circuit base case, hard copy files, and automatics data base, job files, port assignment sheets, breaker files, etc.</span></li> <li style="margin:0.0in 0.0in 0.0in 0.0px;line-height:normal;font-size:11.0pt;font-family:Calibri, sans-serif"><span style="font-size:12.0pt;font-family:Arial, sans-serif;color:black">Review and approve new tools and training prior to rollout</span></li> <li style="margin:0.0in 0.0in 0.0in 0.0px;line-height:normal;font-size:11.0pt;font-family:Calibri, sans-serif"><span style="font-size:12.0pt;font-family:Arial, sans-serif;color:black">Design and set localized RAS schemes based on Operation Engineering requirements</span></li> <li style="margin:0.0in 0.0in 0.0in 0.0px;line-height:normal;font-size:11.0pt;font-family:Calibri, sans-serif"><span style="font-size:12.0pt;font-family:Arial, sans-serif;color:black">Identify existing protection deficiencies</span></li> <li style="margin:0.0in 0.0in 0.0in 0.0px;line-height:normal;font-size:11.0pt;font-family:Calibri, sans-serif"><span style="font-size:12.0pt;font-family:Arial, sans-serif;color:black">The engineer at this level is also assigned to provide normal and emergency maintenance and operation support. The engineer may perform, but not limited to, the following tasks:</span></li> <li style="margin:0.0in 0.0in 0.0in 0.0px;line-height:normal;font-size:11.0pt;font-family:Calibri, sans-serif"><span style="font-size:12.0pt;font-family:Arial, sans-serif;color:black">Provide fault location</span></li> <li style="margin:0.0in 0.0in 0.0in 0.0px;line-height:normal;font-size:11.0pt;font-family:Calibri, sans-serif"><span style="font-size:12.0pt;font-family:Arial, sans-serif;color:black">Investigate questionable relay operations, perform remote event retrieval, and implement corrective actions</span></li> <li style="margin:0.0in 0.0in 0.0in 0.0px;line-height:normal;font-size:11.0pt;font-family:Calibri, sans-serif"><span style="font-size:12.0pt;font-family:Arial, sans-serif;color:black">Process clearance request and provide specific protection setup</span></li> <li style="margin:0.0in 0.0in 0.0in 0.0px;line-height:normal;font-size:11.0pt;font-family:Calibri, sans-serif"><span style="font-size:12.0pt;font-family:Arial, sans-serif;color:black">Assist technicians, operators for routine maintenance and operation work</span></li> <li style="margin:0.0in 0.0in 0.0in 0.0px;line-height:normal;font-size:11.0pt;font-family:Calibri, sans-serif"><span style="font-size:12.0pt;font-family:Arial, sans-serif;color:black">Specific Duties for Transmission Group:</span></li> <li style="margin:0.0in 0.0in 0.0in 0.0px;line-height:normal;font-size:11.0pt;font-family:Calibri, sans-serif"><span style="font-size:12.0pt;font-family:Arial, sans-serif;color:black">Provide project and routine M&O support to Hydro generation</span></li> <li style="margin:0.0in 0.0in 0.0in 0.0px;line-height:normal;font-size:11.0pt;font-family:Calibri, sans-serif"><span style="font-size:12.0pt;font-family:Arial, sans-serif;color:black">Manage digital fault recorders and perform event retrieval</span></li> <li style="margin:0.0in 0.0in 0.0in 0.0px;line-height:normal;font-size:11.0pt;font-family:Calibri, sans-serif"><span style="font-size:12.0pt;font-family:Arial, sans-serif;color:black">Conduct FERC generation interconnection studies and third-party load interconnections</span></li> </ul> <p style="margin:0.0in;line-height:normal;font-size:11.0pt;font-family:Calibri, sans-serif"> </p> <p style="margin:0.0in;line-height:normal;font-size:11.0pt;font-family:Calibri, sans-serif"><span style="font-size:12.0pt;font-family:Arial, sans-serif;color:black">To implement various aspects of the above job responsibilities, the candidate will work with internal engineering, operations, substation construction and maintenance organizations. May attend meetings representing the group, to meet job duties. External contacts are occasional and limited to simple issues.</span></p> <p style="margin:0.0in;line-height:normal;font-size:11.0pt;font-family:Calibri, sans-serif"> </p> <p style="margin:0.0in;line-height:normal;font-size:11.0pt;font-family:Calibri, sans-serif"><strong><span style="font-size:12.0pt;font-family:Arial, sans-serif;color:black">Qualifications</span></strong></p> <p style="margin:0.0in;line-height:normal;font-size:11.0pt;font-family:Calibri, sans-serif"> </p> <p style="margin:0.0in;line-height:normal;font-size:11.0pt;font-family:Calibri, sans-serif"><span style="font-size:12.0pt;font-family:Arial, sans-serif;color:black">Minimum:</span></p> <ul style="margin-bottom:0.0in;margin-top:0.0px"> <li style="margin:0.0in 0.0in 0.0in 0.0px;line-height:normal;font-size:11.0pt;font-family:Calibri, sans-serif"><span style="font-size:12.0pt;font-family:Arial, sans-serif;color:black">Bachelor of Science Degree in Electrical Engineering or a related technical discipline from an accredited curriculum in the US or the equivalent from outside the US</span></li> </ul> <p style="margin:0.0in;line-height:normal;font-size:11.0pt;font-family:Calibri, sans-serif"> </p> <p style="margin:0.0in;line-height:normal;font-size:11.0pt;font-family:Calibri, sans-serif"><span style="font-size:12.0pt;font-family:Arial, sans-serif;color:black">Desired:</span></p> <ul style="margin-bottom:0.0in;margin-top:0.0px"> <li style="margin:0.0in 0.0in 0.0in 0.0px;line-height:normal;font-size:11.0pt;font-family:Calibri, sans-serif"><span style="font-size:12.0pt;font-family:Arial, sans-serif;color:black">EIT Certificate</span></li> <li style="margin:0.0in 0.0in 0.0in 0.0px;line-height:normal;font-size:11.0pt;font-family:Calibri, sans-serif"><span style="font-size:12.0pt;font-family:Arial, sans-serif;color:black">2 years of experience in engineering</span></li> <li style="margin:0.0in 0.0in 0.0in 0.0px;line-height:normal;font-size:11.0pt;font-family:Calibri, sans-serif"><span style="font-size:12.0pt;font-family:Arial, sans-serif;color:black">Able to apply basic engineering principles and theory</span></li> <li style="margin:0.0in 0.0in 0.0in 0.0px;line-height:normal;font-size:11.0pt;font-family:Calibri, sans-serif"><span style="font-size:12.0pt;font-family:Arial, sans-serif;color:black">Basic understanding of symmetrical component theory and ability to perform fault calculations</span></li> <li style="margin:0.0in 0.0in 0.0in 0.0px;line-height:normal;font-size:11.0pt;font-family:Calibri, sans-serif"><span style="font-size:12.0pt;font-family:Arial, sans-serif;color:black">Basic knowledge of logic gate theory and control circuitry</span></li> <li style="margin:0.0in 0.0in 0.0in 0.0px;line-height:normal;font-size:11.0pt;font-family:Calibri, sans-serif"><span style="font-size:12.0pt;font-family:Arial, sans-serif;color:black">Able to read and understand Operating, Single line, SLM&R, and Schematic diagrams</span></li> <li style="margin:0.0in 0.0in 0.0in 0.0px;line-height:normal;font-size:11.0pt;font-family:Calibri, sans-serif"><span style="font-size:12.0pt;font-family:Arial, sans-serif;color:black">Ability to quickly learn system protection concepts and their application</span></li> </ul> <p style="margin:0.0in;line-height:normal;font-size:11.0pt;font-family:Calibri, sans-serif"> </p>